Features:
- “FILTRON 1-10” is Specially designed for automatic filter backwash control, 1-10 station modular controller
- There are DC and AC two types;
- DC controller for 6V or 12V DC power supply, Control two-wire 12V DC latch type electromagnetic head,Conversion of the voltage of the electromagnetic head through the load pump;
- The AC controller contains a built-in transformer,Can use 110V or 220V input power,Provide 24V AC output power for the electromagnetic head;
- The backwash cycle can be triggered simultaneously by time or when the embedded electronic differential pressure sensor reaches the corresponding set value;
- The problem of infinite loops can be solved by detecting whether the predefined number of backwashing limits are exceeded。The controller can additionally control a holding valve / main valve and an alarm output;
- The controller is equipped with a customized LCD display and keyboard;
- The backwash cycle of the controller can be triggered by pressure difference, time and manual。